Agree which dimension the customer is specifying

“Width: 600 mm” is not enough to establish whether a customer means the usable space inside a unit or its overall outside width. A configurator can accept the number correctly and still describe the wrong product if it leaves the measurement basis implicit.

The following fictional storage-unit example concerns communication and approval of a dimension. It is not engineering advice or approval of a product's construction. The supplier's qualified technical process remains responsible for suitability, tolerances and the final specification.

Compare the drawing with the request

Customer request C-16 asks for a clear internal width of 600 mm. The supplier's approved illustrative drawing shows two side panels, each 18 mm thick. For this simple stated arrangement, a 600 mm internal opening corresponds to an outside width of 636 mm.

The website has one field labelled “Width.” It stores 600 and produces an approval summary describing that number as the outside width. Under the same drawing assumptions, a 600 mm outside width would leave only 564 mm internally. The number has survived the form; its meaning has not.

The reviewer inspects the customer's stated need, the drawing's measurement arrows and the generated summary. They do not infer the intended basis from the customer's use of a round number.

Basis Internal width Outside width under this drawing
Customer's stated need 600 mm 636 mm
Old summary's interpretation 564 mm 600 mm

Ask for the basis explicitly

The supplier chooses a form design that names the requested dimension as “Clear internal width” for this product arrangement. The summary shows both the requested internal width and the derived outside width, with the drawing revision that supports the relationship.

A different product construction may require a different calculation or manual review. The implementation must not treat the two-panel arithmetic as a universal rule for all products. If the construction is not established, the summary should identify that uncertainty instead of generating a confident result.

The customer is asked to confirm the displayed basis before the supplier's normal technical approval. In the fictional outcome, C-16 is clarified as 600 mm clear internal width, with 636 mm outside width under drawing D-7. Another unresolved measurement remains marked for review; resolving the width does not approve the whole configuration.

Check the document used for the next decision

The retest follows the form into the approval summary and staff review. Each shows the internal basis, derived external dimension and D-7. The old ambiguous “600 mm width” statement is no longer used as the sole production instruction.

A control request explicitly asking for a 600 mm outside width follows the supported clarification route instead of being silently reinterpreted as an internal measurement. The reviewer also checks that changing the construction does not retain a derived dimension whose assumptions no longer apply.

The result is an agreed specification basis, not a claim that the website has independently verified physical fit. Measurements, tolerances and final manufacturing decisions still need the supplier's appropriate review.

Keep options attached to their evidence

Product selection often combines dimensions, finish, fittings and intended use. Approval should identify the configuration and supporting revision, not merely a generic product name. If a consequential choice changes, the organisation must decide which earlier approvals remain valid.

The specification-document article addresses the related task of showing documents for the correct installation arrangement. For catalogue and ordering work, bring an example where staff currently have to ask “which measurement do you mean?” It can reveal a more useful improvement than adding more options to an already ambiguous form.